上海翻译公司完成PMP说明书英文翻译
时间:2018-04-09 08:54 来源:未知 作者:dl 点击:次
上海翻译公司完成PMP说明书英文翻译
智能压力变速器Intelligent pressure transmission安装使用说明书Installation instructions 北京瑞普恩德斯豪斯仪表有限公司Beijing Endress+Hauser Ripenss Instrumentation Co.,Ltd 第二页 智能压力变速器安装使用说明书Intelligent pressure transmission installation instructions 智能压力变速器是德国E+H公司新近推向市场的智能型仪器 Intelligent pressure transmission is Germany E + H company newly brought to the market of intelligent instruments PMC和PMP的区别在于PMC采用陶瓷传感器,而PMP采用扩散硅传感器 PMC and PMP differ in that PMC uses ceramic sensors and PMP uses diffusion silicon sensors 目录catalogue 技术数据technical data 负载特性load characteristic 普通型电气连接Normal electrical connections 本安型接线框图Intrinsically safe wiring diagram 隔爆型接线和安装应注意explosion proof type connection and installation should pay attention to 本安型安装使用时应注意Intrinsically safe type installation and using should pay attention to 安装方式installation method上海翻译公司完成PMP说明书英文翻译 安装后通过以下方法调整显示表的方向using the following method to adjust the direction of the display after installation 零点满度调节Zero and full adjustment 标定模式下的显示Calibration Mode display 按键设定零点Button to set zero point 按键设定满度Button to set full point 偏压bias voltage 标定Calibration 无显示标定No display calibration 带显示标定Display calibration 阻尼设定damping setting 贮存storage 运输transportation 使用期限service life 产品配套Product Support 第三页: 技术数据technical data 输出output 按用户需要叠加数据信号stack data signal according to user needs 协议agreement 温度影响temperature effect 零点或满度输出zero or full output 线性度linearity 含迁移后量程range including after change 量程比range ratio 迟滞lag 重复性repeatability 预热时间preheating time 响应时间response time 长期漂移long term drift 输出阻尼output damping 允许温度allowable temperature 环境温度environment temperature 普通型ordinary type 本安型Intrinsically safe type 隔爆型flame-proof type 介质温度medium temperature 防爆型explosion proof type 工作电压working voltage 振动影响vibration influence 下述情况无影响Had no effect on the following situation 第四页 振程vibration level 防护等级level of protection 防爆标志explosion-proof sign 本安型Intrinsically safe type 隔爆型flame-proof type 本安型应与以下四种安全栅中的任一种组成本安防爆系统 Intrinsically safe type should combine with either of the following four kinds of safety barrier to be safety explosion protection system 现场显示status display LCD数字LCD Digital 棒图显示或指针式模拟显示(任选件)Bar graph display or pointer analog display(any one) 防爆型explosion proof type 普通型ordinary type 第五页 普通型电气连接Normal electrical connections 检测detection 本安型接线框图Intrinsically safe wiring diagram 安全栅Safety Barrier 危险区danger area 安全区safety area 本安型Intrinsically safe type 第六页 防爆型接线和安装应注意Explosion-proof wiring and installation should pay attention to 开盖前务必切断电源Be sure to cut off power supply before open 接线后或显示表调整方向后,应注意将盖旋紧再用盖侧的金属块通过螺钉压紧在盖的边沿上 After wiring or adjusting display direction, pay attention to tighten it and use metal block by screw clamps on the edge of the cove. 隔爆型电源电压Flameproof power supply voltage 隔爆型选用的电缆线外径,必须与密封圈内径相配Flameproof type’s cable diameter must be matched with the sealing ring inside diameter 变送器外壳设有接地端子,用户在安装使用时应可靠接地 Transmitter shell is equipped with grounding terminals. Should be reliable grounding when used in the installation 用户在安装使用和维护产品时应同时遵守GB50058-92和GB3836.15-2000的有关要求 Users shall comply with GB3836.15-2000 and GB50058-920 on request in the installation and maintenance of the products 电缆引入口应配用经防爆认可的Exd C等级的电缆引入装置 Cable introduce mouth should be equipped with Exd C level of the explosion-proof cable entry device 本安型安装使用时注意Intrinsically safe type should pay attention to when installation and using 变送器必须与安全栅配套使用构成本安防爆系统 Transmitter must be used with safety gate to compose intrinsically safe type explosion protection system 夲安系统的接线请同时参阅产品说明书和安全栅使用说明书 intrinsically safe type system wiring should refer to product specifications and safety barrier operation instruction at the same time 本安系统的布线应尽量避免外界电磁干扰的影响,并将电缆分布参数控制在0.06uf和1mH以内 Intrinsically safe type wiring should avoid the influence of outside electromagnetic interference as far as possible, and cable distribution parameters should be controlled within 0.06 uf and 1 mh 安全栅的安装、使用和维护应遵守安全栅使用说明书 Safety barrier installation operation and maintenance shall comply with the safety barrier operating instructions 用户在安装使用和维护产品时务必认真阅读产品安装使用说明书,并严格遵守和的有关要求要求 Please read the product installation instructions, and strictly comply with relevant requirements ofandin the installation operation and maintenance of this product 变送器外壳设有接地端子,用户在安装使用时应可靠接地 Transmitter shell is equipped with grounding terminals, should be reliable grounding when use in the installation 第七页 安装方式installation mode 直装式:通过螺纹或法兰连接件直接安装于工艺设备,测量精度和安装方向无关 direct-mounted type: installed directly on the process equipment through the threaded or flanged fittings, measurement precision has nothing to do with installation direction 管架式:采用导管引压,用安装支架装于水平管架或垂直管架上(如图) Pipe rack type: using catheter to bring pressure, installed in horizontal or vertical piping support with mounting bracket (as shown in the picture) 墙装:采用导管引压,用安装支架固定于墙面(如图) Wall type: using the pipe to bring pressure, installed to the wall with mounting bracket. (as shown in the picture) 水平管架horizontal pipe rack 垂直管架vertical pipe rack 墙装 wall type 第八页 安装后可以通过以下方法调整显示表的方向 After installation, can use the following method to adjust the direction of the display 松开壳体上的螺钉,壳体可转动270度(注意调整后仍将螺钉旋紧) Loosen the screw on the shell, rotating shell 270 degrees (note adjusted screw tightening) 打开显示窗盖,显示表可90度一级转动到所需位置 Open the display window cover, display table can be turned 90 degrees to the required position 向外推开卡头push the card head out 第九页 零点满度调节zero and full adjustment 压力与电流显示Pressure and current display 两个例子two examples 标定的测量量程Calibrated measuring range 相对压力relative pressure 绝对压力absolute pressure 第十页 标定模式下的显示display of the calibration mode 显示压力零点Display the zero pressure 显示压力满度Display the full pressure 传感器例sensor example 零点zero point 满度full point 量程range 显示display 传感器低限Sensor low limit 传感器高限Sensor high limit 在标定零点和满度期间,条形显示器示出的压力量程和传感器测量范围极限 Between the calibrated zero and full point, bar display shows the pressure range and sensor measurement range limit 反向电流输出Reverse current output 第十一页 按键设定零点Button to set zero point 零点显示zero point display 按+Z或-Z press or 松开两秒后显示返回正常Loosen for two seconds, display returns to normal 按键button 增加零点压力Increase the zero point pressure 按+Z两次之后保持至所需值After press the + Z button twice, keep to the required value 减少零点压力decrease the zero point pressure 按-Z两次之后保持至所需值After press the - Z button twice, keep to the required value 第十二页 按键设定满度Button to set full point 满度显示full point display 按+S或-S press or 松开两秒后显示恢复正常after Loosen for two seconds, the display returns to normal 按键press button 增加满度压力increase full point pressure 按+S两次后保持至所需值After press the + S button twice, keep to the required value 减少满度压力decrease the full point pressure 按-S两次之后保持至所需值After press the- Z button twice, keep to the required value 第十三页 偏压bias voltage 静压柱及方向效应的校正Hydrostatic column and direction effect correction 显示偏压exhibit bias voltage 同时按+Z及+S或同时按-Z及-S,两秒后显示恢复正常 press + S and + Z At the same time or press- Z and the –s at the same time, two seconds later returned to normal 偏压登陆bias voltage landing 按+Z及+S两次press +z and +S twice 清除偏压clear bias voltage 按-Z及-S两次press and twice 第十四页 标定Calibration 一般说明general description 量程零点和满度可以在传感器测量极限内任意设定,注意满度不能小于额定量程的5% zero and full range can be set arbitrarily in sensor measurement, note full range cannot be less than the 5% of rated range 无显示的变送器标定No display transmitter calibration 使用压力标定器施加准确的标准压力Using pressure calibrator accurately sets standard pressure 如果所加标准压力不能和量程零点和满度恰好相等If the standard pressure is not exactly equal to zero and full point range 请按下式计算相关电流press calculate the related current according to the following formula 电流current 接近量程零点的满度或满度的标准压力Close to zero of the full range or full range standard pressure 零点压力zero point pressure 满度压力full point pressure 第十五页 无显示标定No display calibration 两种可能 Two Possibilities 标准压力恰与量程零点和满度相等Standard pressure just equals to zero and full range 施加准确的量程零点压力exert the accurate range zero pressure 例如for example 同时按press at the same time 结果results 施加准确的满度压力exert accurate full pressure 同时按press at the same time 结果results 标准压力接近量程零点和满度压力Standard pressure is close to zero and full range 施加标准压力exert standard pressure 例如for example 计算相应电流值calculate related current 例如,通过按+Z或-Z将其输入For example, enter it by pressing the + Z or Z 结果results 施加标准压力exert standard pressure 例如for example 计算相应电流值,例如,通过按+S或-S将其输入Calculated corresponding current value, for example, by pressing the +S or - S to enter it 结果results 第十六页 带显示标定calibration With display 两种可能two possibilities 标准压力恰与量程零点压力相等Standard pressure equals to the range zero pressure 施加准确的量程零点压力,例如exert accurate range zero pressure, for example 同时按press at the same time 结果results 施加准确的满度压力,例如exert Accurate full pressure, for example 同时按press at the same time 结果results 无标准压力no standard pressure 指定量程零点和满度压力Specifies the range zero and full pressure 按+z或-z直至显示出所期望的量程零点压力,例如press + z or -z until it shows the desired range zero pressure, for example 结果results 按+s或-S直至显示出所期望的量程满度压力,例如press + z or -z until it shows the desired range full pressure, for example 结果results 第十七页 阻尼设定damping set 开关位于位置0时,t也可用手持终端或二次表(例如FMX770)来设定If Switch is located at position 0, t can also be set by hand terminal or secondary tables (for example FMX770) 输入input 输出output 缺省位置1 default location 1 固定阻尼设定Fixed damping Settings 不用don’t use 第十八页 贮存storage 贮存环境温度storage temperature 贮存环境湿度storage humidity 运输transportation 产品在符合包装的条件下运输,在运输过程中防止雨淋,避免受强烈振动与碰撞 Products should be transported under the condition of packaging, preventing rain and avoiding strong vibration and impact 使用期限service life 在用户遵守使用要求、贮存、运输规定的条件下,自用户购进之日起,12个月内因产品质量问题,而不能正常工作时,本公司负责为用户免费修理,更换部件或整机 If users comply with the requirements of usage, storage and transportation conditions, since the purchasing date, within 12 months due to quality problems and can't normal work, the company is responsible for free repair , replacing parts or the whole machine 产品配套Product Support 产品附件accessories of product 电缆密封套cable gland 随机文件files with the machine 安装使用说明installments and operating instructions 安装使用说明书installments and operating instructions 标定证书Calibration certificate 第十九页 北京瑞普恩德斯豪斯仪表有限公司Beijing Endress+Hauser Ripenss Instrumentation Co.,Ltd 北京市朝阳区三元桥霞光里5号Sanyuanqiao Xiaguangli No.5 Beijing Chaoyang District 电话Phone 传真Fax 邮编ZIP北京翻译公司完成PMP说明书英文翻译 世联翻译-让世界自由沟通!专业的全球语言翻译供应商,上海翻译公司专业品牌。丝路沿线56种语言一站式翻译与技术解决方案,专业英语翻译、日语翻译等文档翻译、同传口译、视频翻译、出国外派服务,加速您的全球交付。 世联翻译公司在北京、上海、深圳等国际交往城市设有翻译基地,业务覆盖全国城市。每天有近百万字节的信息和贸易通过世联走向全球!积累了大量政商用户数据,翻译人才库数据,多语种语料库大数据。世联品牌和服务品质已得到政务防务和国际组织、跨国公司和大中型企业等近万用户的认可。 |